My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6312
Public Access
>
City Council Ordinances
>
2001
>
6312
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2004 2:49:07 PM
Creation date
11/5/2014 12:22:56 PM
Metadata
Fields
Template:
City Ordinances
Passed
6/25/2001
Ordinance Number
6312
Bill Number
8536
Introdate
6/4/2001
Description
Adopting the Boca National building Code, fourteenth edition, 1999; Chapter 15.04 Building Code
Introduced By
Schoomer
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(CHAPTER 17 STRUCTURAL TESTS AND INSPECTIONS) <br /> (SECTION 1705.0 SPECIAL INSPECTIONS) <br /> <br />1705.1 General: The permit applicant shall provide special inspections where application is made <br />for construction as described in this section. The special inspectors shall be provided by the permit <br />applicant and shall be qualified and approved for the inspection of the work described herein. <br /> <br /> Exceptions: <br /> <br /> 1. Special inspections are not required for work of a minor nature or where warranted <br /> by conditions in the jurisdiction. <br /> 2. Special inspections are not required for building components unless the design <br /> involves construction documents prepared by a registered design professional per <br /> Section 114.1. <br /> 3. Special inspections are not required for buildings of the R-3 Use Group that do not <br /> involve unusual soil conditions or unusual structural design. <br /> <br /> (CHAPTER 18 FOUNDATIONS AND RETAINING WALLS) <br /> <br /> (SECTION 1806.0 DEPTH OF FOOTINGS) <br /> <br />1806.1.1 Frost line: The fi'ost line is established at 30 inches below finished grade. <br /> <br /> (SECTION 1813.0 WATERPROOFING AND DAMPPROOFING) <br /> <br />1813.3 Dampproof'mg required: Where hydrostatic pressure will not occur as determined by <br />Section 1813.2, floors and walls for other than wood foundation systems and unheated garages shall <br />be dampproofed in accordance with this section. Wood foundation systems shall be constructed in <br />accordance with AFPA TR7 listed in Chapter 35. <br /> <br /> (CHAPTER 21 MASONRY) <br /> <br /> (SECTION 2113.0 MISCELLANEOUS REQUIREMENTS) <br /> <br />2112.3 Support on wood: Masonry shall not be supported on wood griders or other form of wood <br />construction. <br /> <br /> Exceptions: <br /> <br /> 1. Glass-block panels complying with Section 2118.0. <br /> 2. Ornamental fireplace and hearth facings. <br /> <br />20 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.