4. Trees/Shrubs and Tree Grates <br />Installation Expense, Maintenance and Operation <br />A.. Trees and grates <br />shall be installed at the expense of the developer. Upon acceptance of <br />the trees and grates, the City will assume financial responsibility for <br />maintenance. <br />B. An acceptable list of trees is included in the tree schedule. Trees should <br />spacing <br />be planted at a maximum of 40 feet, subject to the approval of <br />the Director of Public Works. The trees should be aligned with new or <br />existing lights.Tree alignment and spacing shall be approved by the <br />Director of Works. <br />Balled and Burlap plants <br />C.: Nursery grown trees dug with firm, natural balls of <br />earth in which they were grown, with ball size not less than the diameter and <br />depth recommended by ANSI Z60.1 for type and size of tree or shrub required; <br />wrapped, tied, rigidly supported, and drum-laced as recommended by <br />ANSI Z60.1. <br />Tree Measurements <br />D.: Measure according to ANSI Z60.1 with branches and <br />trunks or canes in their normal position. Do not prune to obtain required sizes. <br />Take caliper measurements 6 inches (150 mm) above original root ball for trees <br />up to 4-inch (100-mm) caliper size, and 12 inches (300 mm) above ground for 4” <br />caliper trees and larger sizes. Measure main body of tree for height and spread. <br />Warranty. <br />E.The Warranty Period for all plant material is for a period of one year <br />from the date of Substantial Completion or as extended accordingly. The <br />warranty period shall run concurrently with the successful maintenance period <br />established for each plant. <br />Remove and replace all dead plant material immediately or within thirty (30) days <br />of notification by the City. Replace any tree that is dying, scarred, damaged or <br />that has lost its central leader or typical branch structure or in an unhealthy <br />condition as determined by the Architect. The warranty period will begin anew <br />for each replaced tree and continue for a full one-year after each replacement. <br />The contractor is to provide the Architect with a record plan that shows the <br />replaced tree and the date of its replacement. All replacement plant material <br />shall conform to the plant material requirements of the original plant and match <br />the size and branching structure of other typical plants nearby. <br />F. <br />Grade <br />: Provide only “Specimen” quality plant material of sizes and quantity <br />complying with ANSI Z60.1 for type of plant material required. Collected plant <br />material is strictly prohibited unless specifically requested on the drawings. All <br />plant material of one species shall be of matching structure with similar size, <br />height, and spread. Trees of a larger size may be used if acceptable by the <br />Architect and at no additional cost to the Owner. Shade harvested Trees: Balled <br />and burlap, with a straight trunk, well-balanced crown, a straight and strong <br />central leader, of caliper size and branching height indicated, complying with <br />ANSI Z60.1 for type of trees required. <br />G. <br />Gravel Mulch. <br /> 3/8” Pea Gravel, light grey color range. Submit samples for <br />approval by Architect. Do not make substitutions: If specified gravel mulch is not <br />obtainable, submit proof of non-availability to Architect together with proposal for <br />use of equivalent material for review and acceptance by Architect. <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.