My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6312
Public Access
>
City Council Ordinances
>
2001
>
6312
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2004 2:49:07 PM
Creation date
11/5/2014 12:22:56 PM
Metadata
Fields
Template:
City Ordinances
Passed
6/25/2001
Ordinance Number
6312
Bill Number
8536
Introdate
6/4/2001
Description
Adopting the Boca National building Code, fourteenth edition, 1999; Chapter 15.04 Building Code
Introduced By
Schoomer
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
In all areas of Use Group 1-3 at stafflocations. Access to portable extinguishers shall <br />be permitted to be locked. <br />On each completed floor of buildings under construction, other than buildings of Use <br />Group R-3. <br />In any laboratory, shop or other mom used for similar purposes. <br />Where required by the fire prevention code listed in Chapter 35. <br /> <br />(SECTION 922.0 SMOKE CONTROL SYSTEMS) <br /> <br />922.2.4 Activation: Delete in its entirety. <br /> <br />(CHAPTER 13 ENERGY CONSERVATION) <br /> <br />(SECTION 1301.0 GENERAL) <br /> <br />1301.2 Design conditions: The basic design parameters for heating and cooling systems shall be as <br />follows: <br /> <br />Heating Degree Days: <br />Latitude: <br />Solar Factor Value: <br /> <br /> 5000 <br />38° 40' North <br />126 BTU/H/Ft. <br /> <br />Outside Temperature <br />Winter (db) <br />Summer (db) <br />Summer (wb) <br /> <br /> 0°F (-18oc) <br />95°F (35°C) <br />75°F (24°C) <br /> <br />Inside Temperature <br />Winter (db) <br />Summer (db) <br /> <br />70°F (21 °C ) <br />75OF (24oC) <br /> <br />(CHAPTER 16 STRUCTURAL LOADS) <br /> <br />(SECTION 1608.0 SNOW LOADS) <br /> <br />1608.3 Local ground snow loads: For purposes of this code, ground snow loads used in <br />determining the design snow loads for roofs shall be 20 psf. <br /> <br />(SECTION 1609.0 WIND LOADS <br /> <br />1609.3 Local basic wind speed: For purposes of this code the basic wind speed shall be 70 miles <br />per hour. <br /> <br />(SECTION 1610.0 EARTHQUAKE LOADS) <br /> <br />1610.1.3 Local earthquake design criteria: For the purposes of this code the effective peak <br />velocity-related acceleration (A0 and the effective peak velocity acceleration (A0 shallboth be equal <br />to 0.13. <br /> <br />18 <br /> <br /> <br />