Laserfiche WebLink
S <br /> of dust particles into the air. Objectionable views shall <br /> be screened, All trees, bushes or vegetation which over- <br /> hang a public entrance shall be properly trimmed so as to not <br /> obstruct the views and movements of pedestrians or vehicles. <br /> b. Fences shall be:of recognized design standards, properly <br /> installed and protected against decay by an approved protect- <br /> ive coating applied in a workmanlike manner. <br /> 7. Each dwelling and all exterior appurtenances on the premises <br /> shall be adequately protected against rats, mice, termites <br /> and other vermin infestation. Building defects which permit <br /> the entrance of rats, mice, termites and other vermin shall <br /> be corrected immediately by the owner. Tenants shall be re- <br /> sponsible for the elimination ok rodents and vermin from that <br /> part of the premises under their exclusive control except when <br /> more than one unit is infested at the same time and in this <br /> instance the owner shall be responsible for elimination of <br /> the infestation. <br /> B. Building Planning <br /> Room sizes listed in the table following shall be the minimum per- <br /> mitted for any subdividing of existing spaces, or for the con- <br /> struction of any new rooms. Unremodeled existing rooms, where <br /> considered adequate in size and arrangement for the intended func- <br /> tion, may be acceptable if not more than 10 percent smaller than <br /> the minimums given in the following scheduler <br /> Name of <br /> Space (1) Minimum Area (so.ft.) (2) _ Least <br /> i & 2 BR LU 9 or more BR LU Dimension (1) <br /> LR• 140 150 101-0" <br /> DR 8D 100 71-8" <br /> X 50 60 31-0" (4) <br /> K'ette (5) 40 NP 3'-4" <br /> BR 70 70 71-0" <br /> Total BR 1BR; 100 3 BR; 240 lst BR of each <br /> 2BR, 170 4 BR, 340 (LU-81-0" <br /> oHR (6) 70 70 71-011 <br /> LR-DA 160 180 (9) <br /> LR-DR 200 220 (9) <br /> LR-DA-K (7) 210 240 (9) <br /> K-DA 7) 80 100 (9) <br /> K-DR (7) 120 140 (9) <br /> Klette-DA (7) 60 80 <br /> LR-DA-BR (8) 220 -- (9) <br /> LR-BR (8) 190 — (9) <br /> NOTES <br /> (1) Abbreviations <br /> LU m Living Unit Klette= Kitchenette <br /> LR= Living Room BR= Bedroom <br /> DR Dining Room OHR other Habitable Room <br /> DA- Dining Area NF- Not Permitted <br /> K= Kitchen <br /> (2) Minor variations to these areas may be permitted when existing parti- <br /> tions preclude compliance. <br /> (3) Least dimensions shown shall apply'for 90 percent of the required roam <br /> area. Minor variations to these dimensions may be permitted when exist- <br /> ing partitions preclude comjilSywe. <br /> (4) Clear PAAAaaa space. <br /> PRSr page 4 of 9 ��Q�,795CPACL 2487 <br />