Laserfiche WebLink
125.3 Use of O~her Than Official Number: It shall be unlawful for any owner <br />or occupant of a building to use any number other ~han the official number as <br />shown in the records of the Department of Planning and Development. <br /> <br />125.4 Display of Building Numbers~ The aspigned building number shall be <br />displayed in arabic numerals not less than 2 1/2' (64 cm) in height, so that <br />such building number is legible from ~he sLreet and from the alley, if an <br />alley adjoins the premises. <br /> <br />USE GROUP CLASSIFICATION <br /> <br />SECTION 313.0 MIXED USE AND OCCUPANCY <br /> <br />313.1 Two or More Uses: When a building is occupied for two or more uses, <br />not included in the same use group, the building shall comply with Sections <br />313.1.1,313.1.2,313.1.3,313.1.4 or combinations of these sections. <br /> <br />313.1.1 Nonseparated Uses: The required building type of construction shall <br />be determined according to the use of the building which has the more restric- <br />tive height and area limitations. The other requirements of the code shall <br />apply to each portion of the building based on the use of that space except <br />that the most restrictive applicable provisions of Sectin 602.0 and Article t0 <br />shall apply to the nonseparated uses. A fire separation assembly is not <br />required between uses; however, fire separation assemblies shall be provided <br />as required by other sections of the code. <br /> <br />313.1.2 Separated Uses: Each portion of the building shall be individually <br />classified as to use and each such portion shall be completely separated from <br />adjacent portions, both horizontally and vertically, by fire separation walls <br />(Section 910.0) and floor/ceiling assemblies (Section 913.0) having a fire- <br />resistance rating corresponding to the highest fire grading prescribed in <br />Table 902 for the uses being separated. Each such portion of the building <br />shall comply with the code based on the use of that space. Each portion of <br />the building shall comply with the height limitations of Sections 501.0 and <br />503.0 based on the use of that space and the building type of construction. <br />For each story, the building area shall be such that the sum of the ratios of <br />the floor area of each use divided by the allowable area by sections 501.0 and <br />502.0 for each use shall not exceed one. <br /> <br />Exception: The required fire resistance ratings of fire separation <br />walls and floor/ceiling assemblies shall be reduced from those indi- <br />cated by Table 902 by 1 hour, but to not less that 1 hour and to not <br />less than that required by Table 401, where the use does not occupy <br />greater than 10 percent of the allowable area permitted by Sections <br />501.0 and 502.0 based on the use of that space. <br /> <br />313.1.3 Separate Buildings: Each use shall be considered a separate building <br />when each such use is completely separated from adjacent uses by fire walls <br />having a fire resistance rating corresponding to that required by Table 401. <br />Each building shall then comply with the provisions of this code applicable to <br />the use of that building. <br /> <br />313.1.4 Incidental Uses: Where the use is supplemental to the main use of <br />the building and the area devoted to such use does not occupy more than 10 <br />percent of the area of any floor nor more than 10 percent of the allowable <br />area permitted by Sections 501.0 and 502.0 based on the supplemental use, a <br />fire separation assembly shall not be required between the main and supple- <br />mental uses. The required type of construction shall be based on the main use <br />of the building. <br /> <br />Exceptions: Section 313.1.4 shall not apply to: <br />1. Specific use areas within buildings of Use Group 1-2 <br /> (see Section 610.2). <br />2. Specific use areas within buildings of Use Group 1-3 <br /> (see Section 611.7). <br />3. Supplemental areas of Use Group H. <br /> <br /> <br />