My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5966
Public Access
>
City Council Ordinances
>
1994
>
5966
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2004 2:48:12 PM
Creation date
11/5/2014 12:20:38 PM
Metadata
Fields
Template:
City Ordinances
Passed
5/2/1994
Ordinance Number
5966
Bill Number
8181
Introdate
4/18/1994
Description
Amdg Chap 6, Article II, Mechanical Code, to adopt the BOCA National Mechanical Code, Eighth edition, 1993
Introduced By
Schuman
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(CHAPTER 6 BOILERS AND WATER HEATERS) <br /> (SECTION M-604,0 BOH.ER CONNECTIONS) <br />M-604.1 Valves: Every boiler or battery of modular units shall have a shutoff valve <br />in the supply and return piping. For multiple boiler or battery of modular unit <br />installations, each boiler or battery of modular units shall have individual shutoff valves <br />in the supply and return piping. <br /> <br /> (CHAPTER 8 GAS PIPING SYSTEMS) <br /> (SEs,,-alON M-a01,0 GENIIIAL) <br />M-801.6 Referenced Standard: Except as otherwise provided in this code, the <br />insulation, repair and maintenance of gas piping systems shall conform to the standards <br />of the National Fuel Gas Code NFiPA 54-92 as published by the National Fire Protection <br />Association. <br /> (CHAPTER 17 AIR QUALITY) <br /> (SECTION M-1701,0 GENIEPAL) <br />M-1701.3 Enforcement: The local jurisdiction will utilize the services of appropriate <br />county, state or federal agencies for assistanc~ in enforcing the requirements of this <br />article. <br /> (CHAPTER 19 ENERGY CONSERVATION) <br /> (SECTION M-1901,0 GENERAL) <br />M-1900.2 Shnplified Methods: Computations may be based on an approved table of <br />simplified values. <br /> <br /> (SECTION M-1903,0 DESIGN CONDITIONS) <br />M-1903.1.1 Outdoor design parameters: The following design conditions shall <br />be used for calculations under this section: <br /> Heating Degree Days: 4800 <br /> Latitude: 380-40, North <br /> Solar Factor Value: 126 BTU/H/Ft.2 <br /> Outside Temperature: <br /> Winter (db) 0°F (-18°C) <br /> Summer (db) 9S°F (35°C) <br /> Summer (wb) 75°F (24°C) <br /> <br />M-1903.1.2 Indoor Temperature: Indoor design temperatures shall be 70 <br />degrees F (21°C) for heating and 75 degrees F (24°C) for cooling. <br /> <br /> (CHAPTER 20 BOILERS & PRESSURE VESSELS, <br /> MAINTENANCE & INSPECTION) <br /> (SEC-rION M-1001,0 GENERAL) <br />M-2001.4 Boiler Operator Certificate of Fitness: Is hereby deleted in its entirety. <br /> <br />-5- <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.